UTS1004 is the all makes Unit Injector and Unit Pump Test Bench. Currently more than 1000 units actively being used in 75 different countries, prooving its wide range capability and effectiveness.
Technical Specifications
Adjustable Cam Stroke – UTS1004 patented Cam Box design, allows to set the cam stroke without:
| • | Draining oil |
|---|---|
| • | Removing cam |
| • | Adjusting timing |
UTS1004 has the technical infrastructure to test
| • | Caterpillar EUI: 3406E; C15; C10;C11;C12;C13;C18; 3116 MEUI, 3500 MEUI; 3500E. |
|---|---|
| • | Cummins: Celect N14/M11/M11+; HPI (ISX and QSK); K-STC; |
| • | Bosch EUI/EUP all types. |
| • | Delphi: A0; A3; E1; E3; F2P |
| • | Detroit Diesel: all types. |
| • | Continental VDO all types. |
SRT Measurement
| • | UTS1004 is capable to measure the Solenoid Response Time |
|---|
Utilities
| Electricity Requirement | 360-415 Vac 3 phase 50/60 Hz. |
|---|---|
| Electricity Requirement | Transformer must be used when local supply is 200-240 3 phase 60 hz. |
| Electricity Requirement | 100- 240 Vac 1 phase 50/60 Hz for electronics and computer. |
| Air Supply | Min 5 bar, oil and water free @6L/min flow. |
Mechanical Equipment
| Main Motor | 7.5 kW |
|---|---|
| Speed Control | AC Drive: 100 to 1200 rpm |
| Cam Box | Universal Profile, stroke set between 10 and 18 mm. |
Test Oil Transfer System
| Tank | 30 L |
|---|---|
| Pump | 4 L/min; gear type |
| Supply Pressure | 0-25 bar; manually adjusted |
| Return Pressure | 0-6 bar; manually adjusted |
| Test Oil Heater | 2kW |
| Test Oil Cooler | Air Cooled, with -5 °C/min with 4L/min transfer; using a seperate transfer pump |
Instrumentation
| Flow/Delivery | Gear Type Flowmeter; max capacity 1000 mm3/str digitally displayed as graph mm3/str vs time |
|---|---|
| SRT | ±10µs accuracy with respect to real BIP, digitally displayed as graph SRT Value (µs) vs test time |
| Inlet Pressure | 0-25 bar, digitally displayed |
| Return Pressure | 0-6 bar, digitally displayed |
| Supply Temperature | 10-160 °C digitally displayed |
| Return Temperature | 10-160 °C digitally displayed |